top of page

EtherCAT and PLC Integration for Servo Indexers: Wiring, Homing, and Commissioning

5 days ago
8 min read

Introduction

Modern automated production systems require fast, accurate and flexible rotary positioning. Servo indexers are increasingly used in assembly machines, inspection systems, pick-and-aplace applications, welding equipment, packaging machines and rotary transfer systems where programmable positioning is required.

When a servo indexer is integrated with a PLC through EtherCAT, the complete motion system can be controlled electronically. The PLC can coordinate the servo drive, command rotary positions, control indexing speed, execute homing routines and synchronize the indexer with other machine operations.

A typical system consists of:

PLC → EtherCAT Network → Servo Drive → Servo Motor → Servo Indexer

Understanding this architecture is important for machine builders and automation engineers because correct communication, wiring, servo configuration and motion programming directly influence the performance and reliability of the indexing system.

This article explains the fundamentals of EtherCAT and PLC integration for servo indexers, including wiring, homing, motion commands, positioning, troubleshooting and commissioning practices.

 

What Is a Servo Indexer?

A servo indexer is a rotary positioning system driven by a servo motor and servo drive. Unlike a conventional mechanical cam indexer, a servo indexer can provide electronically programmable rotary motion.

The PLC determines the required movement, while the servo drive controls the motor to achieve the commanded position.

Depending on the application, the servo indexer can be programmed for:

●       Different indexing angles

●       Variable indexing speeds

●       Controlled acceleration and deceleration

●       Absolute positioning

●       Relative positioning

●       Homing

●       Multiple rotary positions

●       Synchronization with other servo axes

A servo indexer is therefore particularly useful when a machine needs flexible rotary positioning or frequent product changeovers.

 

What Is EtherCAT?

EtherCAT, or Ethernet for Control Automation Technology, is an industrial Ethernet communication technology widely used for real-time automation and motion-control applications.

In a servo-indexing system, EtherCAT provides communication between the PLC and servo drive.

The PLC can exchange information such as:

●       Target position

●       Actual position

●       Target velocity

●       Actual velocity

●       Control commands

●       Drive status

●       Error information

●       Homing status

●       Position-reached status

This allows the PLC to control the servo indexer as part of the overall machine sequence.

EtherCAT is particularly suitable for multi-axis automation because the communication system is designed for deterministic and synchronized data exchange.

 

EtherCAT and PLC Integration for Servo Indexers

The basic architecture of an EtherCAT servo indexing system is:

PLC / EtherCAT Master↓EtherCAT Communication Network↓Servo Drive↓Servo Motor↓Servo Indexer

The PLC acts as the central controller.

The servo drive receives commands from the PLC and controls the servo motor using closed-loop feedback.

The motor drives the mechanical indexer, which converts motor rotation into controlled rotary-table movement.

 

EtherCAT Wiring for a Servo Indexer

Correct wiring is essential for reliable EtherCAT communication and servo operation.

A typical installation includes separate connections for:


1. Main Power Supply

The servo drive receives the required power supply according to its electrical rating.


2. Servo Motor Cable

The servo motor is connected to the servo drive using the manufacturer's specified motor cable.


3. Encoder Feedback

The encoder provides motor-position feedback to the servo drive.


4. EtherCAT Communication

The EtherCAT cable connects the PLC or EtherCAT master to the servo drive.

A typical network may be:

PLC → Servo Drive 1 → Servo Drive 2 → I/O Device

The actual topology depends on the PLC and EtherCAT devices used.

 

5. Safety Connections

Safety functions such as Safe Torque Off (STO) should be implemented according to the servo drive manufacturer's specifications and the machine's safety design.

 

Important EtherCAT Wiring Practices

For industrial installations, engineers should pay attention to:

●       Proper cable selection

●       Shielding

●       Grounding

●       EMC practices

●       Cable routing

●       Connector quality

●       Separation between power and communication cables

●       Maximum recommended cable length

●       Correct EtherCAT topology

Motor power cables and EtherCAT communication cables should be routed appropriately to reduce electromagnetic interference.

Poor wiring can result in communication errors, intermittent faults or unexpected machine stoppages.

 

Configuring the Servo Drive in the PLC

After completing the physical wiring, the servo drive must be configured in the PLC's EtherCAT environment.

The general procedure is:

  1. Add the EtherCAT master.

  2. Scan or add the servo drive.

  3. Select the correct device description.

  4. Configure the EtherCAT network.

  5. Configure process data.

  6. Set motor parameters.

  7. Configure encoder information.

  8. Select the required operating mode.

  9. Configure position and velocity scaling.

  10. Enable the servo.

  11. Perform the initial motion test.

The exact configuration procedure varies depending on the PLC and servo-drive manufacturer.

 

Understanding the Servo Drive State

A servo drive normally needs to pass through several operating states before motion can be commanded.

A simplified sequence is:

Switch-On Disabled↓Ready to Switch On↓Switched On↓Operation Enabled

The PLC uses control information to request these state transitions, while the servo drive returns status information.

Many EtherCAT servo drives use the CiA 402 drive profile for standardized drive-control functions.

Understanding the drive state is important because a position command alone does not necessarily cause the motor to move. The drive must first be correctly enabled and free from active faults.

 

What Is Homing in a Servo Indexer?

Homing establishes the reference position of the rotary axis.

Before automatic operation, the controller may need to know the mechanical reference position of the indexer.

A typical homing sequence may involve:

Home Sensor → Reference Detection → Position Offset → Home Complete

Depending on the servo system, homing may use:

●       Mechanical home sensor

●       Encoder Z-pulse

●       Absolute encoder position

●       Drive-based homing

●       Controller-based homing

●       Mechanical reference position

The appropriate method depends on the encoder, servo drive and mechanical configuration.

 

Servo Indexer Motion Commands

Once the servo is enabled and homed, the PLC can execute different motion commands.


Absolute Positioning

The PLC commands the axis to move to a specific position.


For example:

Move to 180°

This is useful when each station has a fixed machine coordinate.


Relative Positioning

The axis moves by a specified amount from its current position.


For example:

Move 90°

This is useful for repetitive indexing operations.


Jogging

Jog mode allows the operator to move the rotary table manually during machine setup or maintenance.

 

For example:

Jog ForwardJog Reverse

The PLC can typically control the direction and speed of the jog movement.


Velocity Command

The PLC can command the servo axis to rotate at a specified speed.

This is useful for applications requiring continuous rotary motion rather than fixed-position indexing.

 

Index Time and Dwell Time: Two important parameters in a servo indexing application are index time and dwell time.

Index Time

Index time is the time required for the table to move from one position to another.

Dwell Time

Dwell time is the period during which the table remains stationary at the indexed position.

The table moves to the next position within two seconds and remains stationary for five seconds while the production process takes place.

The PLC coordinates these two stages with the machine operation.

 

Acceleration and Deceleration in Servo Indexing

Acceleration and deceleration have a significant effect on servo indexer performance.

If acceleration is too high:

●       Mechanical shock may increase

●       Vibration may occur

●       Workpieces may shift

●       Servo torque demand may increase

●       Machine components may experience higher stress

If acceleration is too low:

●       Indexing time increases

●       Machine cycle time increases

●       Production capacity may decrease 

 

Position Scaling and Reduction Ratio

Correct position scaling is essential when integrating a servo indexer.

However, the servo motor may rotate several revolutions for one revolution of the output table because of the mechanical reduction ratio.

Therefore, the PLC and servo drive must be configured according to the actual mechanical transmission.

Incorrect scaling can cause:

●       Incorrect table position

●       Incorrect speed

●       Excessive motor rotation

●       Positioning errors

●       Unexpected machine movement

The mechanical reduction ratio should therefore be confirmed before commissioning.

 

Typical PLC Sequence for a Servo Indexer

A basic automatic sequence can be structured as follows:


Step 1 – Safety Check

Confirm that all required safety conditions are satisfied.


Step 2 – Servo Ready

Check the servo-drive status.


Step 3 – Servo Enable

Enable the servo axis.


Step 4 – Homing

Execute the homing procedure if required.


Step 5 – Home Confirmation

Confirm that the home operation has been completed successfully.


Step 6 – Index Command

Send the required target position.


Step 7 – Motion

The servo motor accelerates and rotates the indexer.


Step 8 – Position Reached

The PLC monitors the drive status.


Step 9 – Station Operation

Once the table reaches the required position, the station operation begins.


Step 10 – Next Index

After the process is complete, the PLC commands the next position.

This sequence continues throughout the automatic production cycle.

 

Servo Indexer Troubleshooting

Servo Does Not Enable

Check:

●       Main power supply

●       Servo alarm

●       STO circuit

●       Control sequence

●       EtherCAT communication

●       Drive state

 

EtherCAT Communication Error

Check:

●       EtherCAT cable

●       Connectors

●       Shielding

●       Device configuration

●       Network topology

●       PLC EtherCAT configuration

●       Drive communication status

 

Homing Does Not Complete

Check:

●       Home sensor

●       Sensor wiring

●       Homing direction

●       Homing speed

●       Encoder feedback

●       Home offset

●       Software limits

 

Incorrect Position

Check:

●       Mechanical reduction ratio

●       Position scaling

●       Encoder configuration

●       Home position

●       Commanded position

●       Mechanical coupling

 

Excessive Vibration

Check:

●       Acceleration and deceleration settings

●       Servo tuning

●       Payload

●       Moment of inertia

●       Mechanical rigidity

●       Coupling

●       Indexer mounting

 

Best Practices for EtherCAT Servo Indexer Commissioning

A systematic commissioning procedure can significantly reduce startup problems.


1. Verify Mechanical Selection

Confirm the indexers:

●       Payload capacity

●       Axial load capacity

●       Radial load capacity

●       Allowable moment

●       Inertia capacity

●       Hollow bore

●       Required index time


2. Verify Servo Compatibility

Ensure that the selected motor and servo drive are compatible with the indexer and application.


3. Confirm Reduction Ratio

Verify the complete motor-to-output reduction ratio before configuring PLC scaling.


4. Check EtherCAT Communication

Confirm that the PLC recognizes the servo drive correctly.


5. Configure the Drive

Set motor, encoder, operating mode and motion parameters.


6. Perform Homing

Establish the machine reference position.


7. Test at Low Speed

Verify direction, position and mechanical movement before running at production speed.


8. Test the Complete Cycle

Check indexing, dwell, station operation and subsequent indexing.


9. Verify Safety Functions

Check emergency-stop and STO functions before automatic operation.

 

 

Servo Indexer Applications in Industrial Automation

The combination of a servo indexer, servo drive and EtherCAT PLC is suitable for many automation applications.


Automatic Assembly

A rotary table can transfer components between multiple assembly stations.


Vision Inspection

The PLC can position products at predetermined inspection locations.


Robotic Pick-and-Place

The servo indexer can present products to a robot at precise positions.


Welding

Components can be rotated to programmed welding positions.


Packaging

The indexer can synchronize product positioning with filling, sealing and labeling operations.


Testing Machines

Products can be positioned accurately at multiple testing stations.

 

How to Select the Right Servo Indexer

Before selecting a servo indexer, the application should be evaluated based on more than just motor power.

Important parameters include:


Mechanical Parameters

●       Payload

●       Moment of inertia

●       Axial force

●       Radial force

●       Radial moment

●       Centre of gravity

●       Mounting arrangement

●       Hollow-bore requirement


Motion Parameters

●       Index angle

●       Index time

●       Dwell time

●       Maximum speed

●       Acceleration

●       Deceleration

●       Cycle time


Control Parameters

●       PLC manufacturer

●       EtherCAT compatibility

●       Servo-drive compatibility

●       Encoder type

●       Homing method

●       Positioning resolution

●       Communication requirements


Application Parameters

●       Required accuracy

●       Repeatability

●       Production rate

●       Environmental conditions

●       Space limitations

●       Safety requirements

Correct selection of these parameters helps ensure that the servo indexer, servo motor and drive operate within their recommended limits.

 

Conclusion

EtherCAT and PLC integration for servo indexers provides an effective solution for modern rotary automation systems requiring accurate and programmable motion.

The PLC acts as the central machine controller, while EtherCAT provides communication between the PLC and servo drive. The servo drive controls the motor, and the servo indexer converts the motor movement into precise rotary positioning.

A successful system depends on correct mechanical sizing, EtherCAT wiring, servo-drive configuration, homing, position scaling, acceleration and motion-command programming.

For machine builders, the complete system should always be evaluated as:

PLC → EtherCAT → Servo Drive → Servo Motor → Servo Indexer → Rotary Table

When these elements are correctly selected and commissioned, a servo indexing system can provide accurate positioning, flexible motion control and reliable synchronization with other automation processes.

For applications requiring high productivity and programmable rotary positioning, an EtherCAT-connected servo indexer can be an important part of a modern automated production line.

 
 
 

Comments